When there is a fire around the products, should ensure that it will not to cause the spread of the fire, horizontal-vertical burning test simulates electronic products around the environment in the early condition, using the simulation technology to assess the fire risk. The test equipment apply to the electrical and electronic product components of household appliances, spare parts and components, such as: household appliances insulation shell, Panel switches, printed circuit boards and insulation materials and so on.
Technical Parameter
Kinds | 500W(5V class) |
Burning tester | 500W(burning test for V-0,V-1,V-2 classification) |
Burner Tube | Internal diameter: Φ 9.5mm±0.3mm |
Burning Angle | 0°,20°,45° |
Thermocouple | Type K (Ni/Cr - Ni/Al) |
Thermocouple Size | 0.5 mm |
Standard Copper | Block Φ9mm±0.01mm,weight:10g±0.05g before drilling. |
Time for Temperature to Increase | From 100°C±5°C to 700°C±3°C;54s±2s (preset) |
Gas Flow | 965±32ml/min |
Gas Supply | methane,min.98% purity |
water-column | 125m±5mm |
Test Time | 54±2s |
Flame Height Indicator | 40±1mm |
Volume Of Chamber | >0.5m³, black interior |
Conform to standard | UL94,IEC60695-11-3,IEC60695-11-20 |